This insulation calculator converts a target R-value into a thickness for the material you are using, and shows what the recommendation is for your climate zone. Different materials need very different depths to reach the same number.
It depends on where you live, and the US Department of Energy publishes the recommendation by climate zone through ENERGY STAR.
| Zone | Attic | Floor |
|---|---|---|
| 1 | R30 | R13 |
| 2 | R49 | R13 |
| 3 | R49 | R19 |
| 4 | R60 | R19 |
| 5 and 6 | R60 | R30 |
| 7 and 8 | R60 | R38 |
Spec ENERGY STAR Recommended Home Insulation R-Values, administered by the US Department of Energy and EPA, based on the 2021 IECC residential provisions. Checked August 2026.
Very different depths depending on the material, which is the practical question the R-value alone does not answer.
| Material | R per inch | Inches for R49 |
|---|---|---|
| Fibreglass batt | 3.1 - 3.8 | about 14 |
| Blown fibreglass | 2.2 - 2.9 | about 19 |
| Blown cellulose | 3.2 - 3.8 | about 14 |
| Open-cell spray foam | 3.5 - 3.7 | about 14 |
| Closed-cell spray foam | 6.0 - 7.0 | about 8 |
| EPS rigid board | 3.6 - 4.2 | about 13 |
| Polyiso rigid board | 5.6 - 6.5 | about 8 |
Spec R-per-inch values are manufacturer ranges and vary by product. Check the specific product data sheet. Polyiso performs less well in cold temperatures, which matters in unheated attics in northern zones.
Because the studs are not insulated. Heat takes the easy path through the timber, which is roughly R-1 per inch against R-3.5 for the insulation beside it. This is thermal bridging, and it means a wall built with R-13 batts performs closer to R-12 overall once the framing is counted.
It is also why continuous exterior insulation is increasingly specified: a layer of rigid board over the studs breaks the bridge in a way that no amount of cavity insulation can.